The following table shows the possible DRIVE STATUS indications that can appear on the drive display:
DRIVE STATUS TABLE
DISPLAY DESCRIPTION
STOP Drive is in STOP mode - No output to the motor.
RUN Drive is in RUN mode and is within
+
/-3Hzofthespeedsetpoint.
FAULT Drive has shut down due to a FAULT condition. If the fault condition has
passed,pressingtheSTOPkeywillclearthefaultandreturnthedrivetothe
STOP mode.
LOCK Drive is in FAULT LOCKOUT due to five unsuccessful restart attempts.
BRAKE DCBRAKEisenergized.
LIMIT Drive is in CURRENT LIMIT due to an overloaded motor, or ACCEL is too
fast.
FDEC Drive is in DECEL FREEZE because DECEL is too fast.