12.0 INITIAL POWER UP
Hazardofelectricalshock.Disconnectincomingpowerandwaitthreeminutesbeforeservicing
the drive. Capacitors retain charge after power is removed.
Beforeattemptingtooperatethedrive,motor,anddrivenequipmentbesureallprocedurespertainingto
installation and wiring have been properly followed.
Severe damage to the drive can result if it is operated after a long period of storage or inactivity
withoutreformingtheDCbuscapacitors!
Ifinputpowerhasnotbeenappliedtothedriveforaperiodoftimeexceeding6months(duetostorage,
etc),theelectrolyticDCbuscapacitorswithinthedrivecanchangeinternally,resultinginexcessiveleakage
current. This can result in premature failure of the capacitors if the drive is operated after such a long
period of inactivity or storage.
In order to reform the capacitors and prepare the drive for operation after a long period of inactivity, apply
input power to the drive for 2 hours prior to actually operating the drive/motor system.
Disconnectthedrivenloadfromthemotor.Verifythatthedriveinputterminals(L1,L2,andL3)arewired
to the proper input voltage per the nameplate rating of the drive.
DONOTconnectincomingACpowertooutputterminalsT1,T2,andT3!Donotcycleinput
power to the drive more than once every two minutes. Damage to the drive will result.
Energizetheincomingpowerline.TheLCDdisplayshouldlightandflash“TESTING”andthenshow
thevoltageandhorsepowerratingofthedrive.Thedisplayshouldthenshow“STOP>20.00HZ”which
indicatesthatthedriveisstopped,forwarddirectionisselected,andthespeedsetpointis20.00Hz:
If the display does not appear, remove the incoming power, wait three minutes for the bus capacitors to
discharge, and verify correct installation and wiring. If the wiring is correct, re-apply incoming power and
note the display for drive status. If the display still does not appear call the factory for assistance. If the drive
powersupcorrectly,followtheproceduregivenbelowtocheckthemotorrotation:
1. Usethe“Down”arrowkeytodecreasethespeedsetpointtotheminimumvalueallowed(.50Hzif
Parameter10-MINFRQhasnotbeenchanged).
2. Pressthe “START”key.ThedriveshouldindicateRUN, butifthespeedsetpointis.50Hz,the
motormaynotrotate.Pressthe“UP”arrowkeytoincreasethespeedsetpointuntilthemotorstarts
to rotate.