3. If the motor is rotating in the wrong direction, press the “STOP” key, remove power from the
drive, wait three minutes for the bus capacitors to discharge, and swap any two of the motor wires
connected to T1, T2, and T3.
NOTE 1: The drive is phase insensitive with respect to incoming line voltage. Therefore, to change the
motor rotation, the phases must be swapped at the drive output terminals or at the motor.
NOTE 2:Ifthedrive’sdisplayisblankafterpowerup,anditisamodelequippedwithheatsinkfans,check
tomakesurethefansareoperating(theyshouldbespinninganytimepowerisappliedtothedrive).Ifthey
arenotspinning,thedrive’sdisplaywillbeblankandthedrivecannotbeoperated.Ifthefansareclogged
orjammed,disconnectpowerfromthedriveandremoveanyobstructionsfromthefans.Reapplypower
tothedriveandcheckthefans.Iftheyarespinning,thedrive’sdisplayshouldappearandthedriveshould
operate properly. If there are no obstructions, the fan itself may be defective. Please contact the factory for
assistance.
13.0 KEYPAD CONTROL
Thedrivecanbeoperatedinanumberofdifferentways:keypad(LOCAL),controldeviceswiredtothe
terminalstrip(REMOTE),oracombinationoftheterminalstripandthekeypad.Thedriveshouldfirst
beoperatedfromthekeypadduringinitialstart-up.RefertoSections14.0-CONTROLWIRING,and
18.0 - DESCRIPTION OF PARAMETERS for information on remote operation.
13.1 KEYPAD FUNCTIONS
START/STOP Tostartthedrive,presstheSTARTkey.Tostopthedrive,presstheSTOP
key.
NOTE:TheSTOPkeyisactiveinbothLOCALandREMOTEmodes.
SPEEDsetpoint Toincreasethespeedsetpoint,presstheUParrowkey.Todecreasethe
speedsetpoint,presstheDOWNarrowkey.
FORWARD/REVERSE Tochangerotationdirection,presstheFWD/REVkeyandthenpressthe
ENTERkeywithinthreeseconds.
NOTE: Parameter 27 - ROTATION must be set to FWD & REV for this
keytobeactive.
AUTO/MANUAL To toggle between AUTOMATIC (terminal strip) andMANUAL (key-
pad)speedcontrol,presstheAUTO/MANkeyandthenpresstheENTER
keywithinthreeseconds.
NOTE:Parameter28-AUTO/MANmustbesettoBOTHforthiskey
to be active. See Section 14.0 - CONTROL WIRING for information on
automatic speed references.
FAULTRESET Use the STOP key to reset a fault. If the fault condition has passed,
pressingtheSTOPkeywillresetthefaultandreturnthedrivetoaSTOP
condition.
NOTE: If an OUTPUT fault occurs, there will be a 30 second delay before
thefaultcanbeclearedusingtheSTOPkey.