Leeson FHP Series NEMA 4x 175326 Quick Start Guide Bedienungsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
STEP #4
Configure jumpers JMP501 and JMP502 on the bottom board for 115 or 230 VAC Power Input.
J
MP
502
J
MP
501
STEP #2
Configure jumpers JMP504 and JMP505 on the top board for the appropriate signal input.
J
MP
50
4
1 2
3
1 2
3
J
MP
505
1 2
3
J
MP
505
JMP504 (on top board)
Pins 1 & 2 for Voltage Input, or using a speed pot.
Pins 2 & 3 for Current Input
JMP505 (on top board)
Pins in Column 1 for 0 - 5 VDC Voltage Input,
or using a speed pot
Pins in Column 2 for 0 - 10 VDC Voltage Input
Pins in Column 3 for 4 - 20 mA Current Input
exam
p
le
:
STEP #3
Configure jumpers JMP503 on the bottom board and JMP506 on the top board.
MP
JMP503 (on bottom board)
Pins 1 & 2 to Trip
Pins 2
&
3 to Restar
t
TRIP: Drive has a low volta
g
e fault & mus
t
be manuall
y
re-enabled to restart
.
RESTART: Drive has a low volta
g
e fault
&
will momentaril
y
stop then auto-restar
t
when input volta
g
e returns to minimum level
.
U
V TRIP
R
E
S
TAR
T
1
2
3
MP
JMP506 (on top board)
Pins 1 & 2 to Brake
Pins 2 & 3 to Coast
BRAKE
CO
A
ST
1
2
3
CONNECTIONS
STEP #5
Connect motor leads of a 3-
phase motor to U, V, and W
(TB502 on BOTTOM board)
using 14 - 16 AWG wire as
shown in the figure below.
STEP #6
Connect 115 or 230 VAC power
input using 12 AWG wire.
NOTE: LEESON strongly
recommends installing an
emergency stop switch on both
the L1 and L2 inputs.
STEP #1-skip this step if provided FWD/OFF/REV and speed potentiometer will be used.
Otherwise disconnect factory-wired connections from the FWD/OFF/REV switch and speed
potentiometer. Connect the enable/disable switch, direction switch, and speed potentiometer or
signal input to TB501 on the TOP board using 20 - 24 AWG wire as shown below.
DIRECTION
SWITCH
ENABLE/DISABLE
SWITCH
(open to disable)
NOTE:
The
f
actor
y
-wired spee
d
potentiometer on the
case cover must be
disconnected prior to
wirin
g
to a si
g
nal input
TO SPEED POT
OR SIGNAL INPUT
Copyright 2003 by LEESON Electric - All rights reserved. No part of this document may be reproduced or transmitted in any form without
written permission from LEESON Electric. The information and technical data in this document are subject to change without notice. LEESON
Electric makes no warranty of any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability
and fitness for a given purpose. LEESON Electric assumes no responsibility for any errors that may appear in this document and make no
commitment to update or to keep current the information in this document.
kc0504
LEESON Electric
www.leeson.com
2100 Washington Street, Grafton, WI 53024-0241, USA
Phone: 262-377-8810 Fax: 262-377-9025
Document Number: 250-0389, Revision 0; Printed in the U.S.A. - May 2004