16 Calibration
3. Lock the motor armature. Be sure that the motor is firmly
mounted.
4. Connect power to the drive. The motor should remain
stopped.
5. Set the speed adjust potentiometer to maximum (full CW).
6. Adjust the TORQUE trimpot CW slowly until the armature
current is 120% of motor rated armature current.
7. Set the speed adjust potentiometer to minimum and
remove power from the drive.
8. Remove the stall from the motor.
TORQUE (cont.)